| Certificates | NZECS (NZ-ECs), in common use for RE100. I-REC(E) since 2023 |
| Issuers | NZECS: BraveTrace, a private registry. I-REC: Energy Market Services, Transpower's commercial division |
| NZ-ECs redeemed | 2.6 million in the year to March 2026, by 419 energy users (BraveTrace, interim) |
| I-RECs issued | 0.45 million MWh in 2025, and 0.38 million MWh from January to September 2026, all redeemed in New Zealand |
| Grid | 89% renewable in 2025, according to Ember: hydro 55%, geothermal 22%, wind 10%. Gas makes up 9% |
| Grid emission factor | 0.0787 kg CO2-e/kWh, 2025 average (Ministry for the Environment) |
Why the grid mix is not enough
RE100's FAQ answers this directly: renewable electricity can be actively procured in New Zealand, so a claim to the grid mix double-claims power that other companies have bought for themselves. A New Zealand site needs certificates for an RE100 claim.
Two systems
NZECS started in 2018 and is now run by BraveTrace, a private company. It is the larger system, certifying just over 6% of New Zealand's electricity. It accepts wind, hydro, solar and landfill gas but not geothermal, and 61% of its certificates now come from wind or solar. Companies usually buy through a participant, often their electricity retailer, or through brokers.
I-RECs were approved in October 2023 with Transpower's Energy Market Services as issuer, and the first were issued in February 2025. I-TRACK's own assessment says NZECS is not affiliated with I-REC. The four I-REC devices do not appear on BraveTrace's device list.
I-REC supply
Evident's device register names four devices. Three are Contact Energy stations, matched by name: the Te Mihi (166 MW, 2014) and Te Huka Unit 3 (51.4 MW, 2024) geothermal plants and the Roxburgh hydro dam (320 MW, 1956). The fourth is the Ngāwhā unit 3 geothermal plant in Northland (2020), which Top Energy runs. Contact sells all of Te Huka 3's renewable attributes to Microsoft under a ten-year agreement, though its release does not say they are I-RECs.
- 2025
- 0.45
- 2026, Jan to Sep
- 0.38
Source: Xpansiv I-REC Registry, by date of issue. 2026 covers nine months only.
Plant age
The three geothermal units pass RE100's 15-year rule: Te Mihi up to claim year 2029, Ngāwhā 3 up to 2035 and Te Huka 3 up to 2039. Roxburgh fails, and it was 23% of 2026 I-REC issuance. NZECS supply young enough for RE100 is tight: BraveTrace reports that it fell 1.7% in the year to March 2026 while redemptions of it rose 20%. Ask for the device and its commissioning date in either system.
Geothermal emissions
New Zealand geothermal plants release CO2 from the steam field, and they are covered by the emissions trading scheme. The ministry's grid factor includes those emissions. So a geothermal I-REC may not support a zero emission factor in a market-based inventory. Check the emission rate on the certificate or redemption statement.
Emission factors and residual mix
The Ministry for the Environment publishes location-based grid factors only: 0.0787 kg CO2-e/kWh for 2025. Its guide says nothing about certificates. The government publishes no residual mix. BraveTrace publishes a quarterly residual factor, but it deducts only NZ-ECs, not I-RECs, and I-TRACK models its own. In December 2025 the External Reporting Board, which sets New Zealand's climate reporting standards, said there is no single source for a residual factor and that the two unregulated registries create a double-counting risk.
Under the climate-related disclosures regime, about 200 large entities must report Scope 2 on a location basis. A market-based figure is optional.
Buying electricity
New Zealand has had full retail competition since 1999, so any business can choose its retailer, and many buy NZ-ECs through it. Corporate PPAs are mostly financial contracts alongside a normal supply contract, and suit loads far above a few thousand MWh. Whatever the route, make sure the contract allocates the certificates and that they are redeemed in your name.
Before you buy
- Check which system your group policy accepts. RE100 lists NZECS as in common use, and both NZECS and I-REC as recognised systems.
- Ask for the device and its commissioning date. For RE100, avoid Roxburgh or count it in your 15% allowance for older plants.
- For geothermal I-RECs, check the emission rate shown on the certificate.
- Make sure the redemption names your New Zealand legal entity and gives New Zealand as the location of consumption. See redemption statements.